Products
| HS Code | 848040 |
| Product Name | MG Chemicals 99.9% Isopropyl Alcohol Electronics Cleaner |
| Part Number | 824 |
| Chemical Name | Isopropyl alcohol |
| Cas Number | 67-63-0 |
| Molecular Formula | C3H8O |
| Purity | 99.9% |
| Physical Form | Liquid |
| Color | Colorless |
| Odor | Alcohol-like |
| Flash Point | 11.7°C (53°F) closed cup |
| Boiling Point | 82.5°C (180.5°F) |
| Evaporation Rate | Fast |
| Residue | None after evaporation |
| Specific Gravity | 0.786 at 20°C |
| Shelf Life | 2 years from date of manufacture |
As an accredited MG Chemicals 99.9% Isopropyl Alcohol Electronics Cleaner factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | A 1-liter bottle of MG Chemicals 99.9% isopropyl alcohol electronics cleaner, with a secure, resealable cap for safe, precise use. |
| Container Loading (20′ FCL) | 20′ FCL: 20 pallets with cartons of 99.9% IPA, secured upright, segregated, and ventilated as flammable liquid. |
| Shipping | This flammable liquid ships via ground transportation only, in accordance with hazardous materials regulations. Proper packaging and labeling are required, and a hazmat handling fee may apply. Air, expedited, and international shipping are not available. An adult signature may be required upon delivery. |
| Storage | Store in a cool, dry, well-ventilated area away from heat, sparks, open flames, and direct sunlight. Keep the container tightly closed when not in use, and store upright to prevent leaks. Avoid contact with strong oxidizers. Use secondary containment if possible, and keep away from ignition sources. |
| Shelf Life | Shelf life is essentially indefinite if stored sealed, away from heat and moisture; evaporation or contamination reduces effectiveness. |
This application section defines process envelopes for the MG Chemicals 99.9% isopropyl alcohol electronics cleaner across six downstream manufacturing operations where polar solvent action is required for flux residue dissolution, particulate displacement, and moisture displacement. The solvent is supplied as a low-water, non-blended formulation with a closed-cup flash point of 11.7 °C, saturated vapour pressure of 4.32 kPa at 20 °C, and a lower flammable limit of 2.0 vol%. All process equipment must therefore be grounded and ventilated to maintain vapour concentrations below 2.0 vol%. Each of the following application profiles lists the applicable compliance framework, use concentration, production method, and terminal article class.
In printed circuit board assembly lines running SnAgCu reflow profiles with peak temperatures from 235 °C to 250 °C, the organic acid activators contained in rosin-containing and no-clean solder pastes remain as a hygroscopic film after reflow. On production-scale inline washers operating at 0.8–1.2 m/min conveyor speed, the cleaner is sprayed undiluted at 99.9% concentration through a stainless-steel manifold at 30–50 psi, followed by an unheated air knife at 20–30 s dwell to displace dissolved residues from the laminate surface. The application ratio is 100 parts cleaner to 0 parts deionized water. The applicable cleanliness acceptance framework is IPC-J-STD-001G Section 8, with ionic contamination measured by IPC-TM-650 2.3.25 resistivity of solvent extract; Class 3 assemblies are released only when the extracted ionic contamination remains below 1.56 µg/cm² sodium chloride equivalence. Surface insulation resistance is confirmed by IPC-TM-650 2.6.3.7 at 85 °C and 85 %RH, with a minimum insulation resistance of 100 MΩ. No deionized water is added to the sump for this application; any dilution below 99.9% must be validated by non-volatile residue testing and drying-time studies because water raises the heat of vaporization and leaves residual water films under low-standoff components. The terminal finished product classes include automotive engine control units, server power modules, medical diagnostic electronics, and consumer handsets requiring Class 3 cleanliness. The process boundary is relative humidity-dependent: above 60 %RH the solvent absorbs atmospheric water at a rate sufficient to increase ionic background; therefore sump covers, nitrogen blanketing, or moisture monitoring are specified for humid production floors.
Solder paste printing on 0.3 mm pitch ball-grid-array packages uses Type 4 or Type 5 solder powder dispersed in a thixotropic flux vehicle with a typical viscosity of 800–1,200 kcps at 25 °C; aperture blockage becomes a yield-limiting defect when the area ratio falls below 0.66. The cleaning material is applied undiluted at 99.9% in an automatic understencil cleaning system, with a solvent dosing of 0.8–1.2 mL per 500 mm stroke length and a vacuum extraction pulse of 0.2–0.4 bar immediately after the wipe paper contact. The application ratio is 100 parts cleaner to 0 parts deionized water. Compliance for stencil design and solder paste release is anchored to IPC-7525B and IPC-J-STD-005A, while the final assembled board is inspected to IPC-A-610H Class 3 cleanliness requirements. The production method alternates wet wipe, dry wipe, and vacuum every 1–2 printed panels for fine-pitch designs; the solvent dissolves flux vehicle residues inside the aperture at the edge meniscus, while the dry wipe removes the suspension before solvent evaporation can re-deposit solids. The low surface tension of the 99.9% IPA, measured at 21.7 mN/m at 20 °C, permits wetting of aperture sidewalls with area ratios down to 0.66. Terminal products include high-density interconnect smartphone motherboards, RF front-end modules, and tablet mainboards using 0.3 mm pitch BGA and 0.4 mm pitch QFP footprints. The process boundary is that bulk solvent accumulation in the wipe paper must be controlled; saturated wipes transfer solvent to the stencil underside and cause paste dilution at the aperture rim, producing bridging. Because the flash point is 11.7 °C, the stencil cleaner cabinet is fitted with local exhaust and the wipe paper receptacle is closed to prevent vapour accumulation above 2.0 vol%.
For fibre optic connector end-face cleaning in patch-cord assembly and network installation, a 99.9% isopropyl alcohol cleaner is used undiluted because the residual water content of lower grades introduces non-volatile conduction paths across the ceramic ferrule end-face. The application ratio is 100 parts cleaner to 0 parts deionized water; a saturated cleanroom swab is prepared with 0.05–0.10 mL of liquid, and the end-face is drawn from the centre to the outer edge in 3 unidirectional passes. The cleaning method itself is selected under IEC 62627-01, while compliance is evaluated per IEC 61300-3-35, with automated inspection at 400× magnification classifying scratches, pits, and contamination defects by zone; the allowed defect thresholds for single-mode PC connectors are tighter in the core zone of 25 µm diameter. The terminal finished product types include LC, SC, E2000, and MPO-12/24 connectors, pigtails, and fibre distribution modules. In production, the wet cleaning step is followed immediately by a dry swab pass to remove the solvent film before it can creep into the ferrule bore and attack the epoxy bead. The operational boundary is that the swab must not be re-dipped into the stock bottle after contacting the end-face, because particulate and ionic contamination transferred back into the bottle produces cumulative failure signatures that are not visible until post-inspection loss measurements exceed 0.3 dB insertion-loss budgets.
| Downstream scenario | Primary compliance standard | Measurement or inspection method | Use concentration |
|---|---|---|---|
| Post-reflow PCB flux removal | IPC-J-STD-001G Section 8 | IPC-TM-650 2.3.25, IPC-TM-650 2.6.3.7 | 100 parts product / 0 parts DI water |
| SMT stencil aperture cleaning | IPC-7525B, IPC-J-STD-005A | IPC-A-610H Class 3, paste print inspection | 100 parts product / 0 parts DI water |
| Fibre optic connector end-face cleaning | IEC 62627-01, IEC 61300-3-35 | Automated end-face inspection at 400× | 100 parts product / 0 parts DI water |
| Semiconductor wafer dicing cleanup | ISO 14644-1 Class 5, ASTM D770-11(2019) | Resistivity extraction, particle counting | 100 parts product / 0 parts DI water |
| Display lamination pre-clean | ISO 14644-1 Class 5/7 | Laser particle counter at 0.3 µm and 0.5 µm | 100 parts product / 0 parts DI water |
| Conformal coating rework | IPC-7711/21, IPC-CC-830B | IPC-A-610H Class 3, ionic contamination extraction | 100 parts product / 0 parts DI water |
The singulation of silicon wafers on dicing saws using diamond blades of 20–35 µm width leaves a slurry of silicon dust, metal fines, and coolant surfactants on the die edges and streets. In this application, the 99.9% isopropyl alcohol cleaner is applied undiluted onto the rotating wafer surface after the initial deionized water rinse; the use ratio is 100 parts product to 0 parts water, and the liquid is dispensed through a low-pressure nozzle at 0.5–1.0 L/min while the chuck rotates at 800–1,200 rpm. This sequence displaces low-surface-tension coolant films and accelerates final drying, but it must be preceded by a water rinse of sufficient volume to remove the bulk of water-soluble coolant components. Compliance in wafer-level processing is aligned with ISO 14644-1 Class 5 cleanroom limits for airborne particles, which permits no more than 3 520 particles/m³ at 0.5 µm, and with ASTM D770-11(2019) for isopropyl alcohol grade. The terminal finished product types are memory die, MEMS inertial sensors, power MOSFETs, and open-cavity packages that require post-singulation cleanliness before die attach. The process conflict is the exposure of low-κ dielectric materials to polar solvents; published data for specific 45 nm and 28 nm node low-κ films is limited, but certain organosilicate glass dielectrics may exhibit temporary solvent uptake that requires a post-clean bake at 120 °C for 30 minutes before die attach. The operational boundary is that ionic cleanliness of the final die surface is verified by extraction with 10 mL of 18.2 MΩ·cm deionized water and measured resistivity, and the lot is released only when the extract conductivity is below the specified equipment baseline.
Before optical bonding or lamination of cover glass to TFT-LCD and OLED display cells, the substrate surfaces must be free of polarizer edge oils, adhesive transfer residues, and glass dust. The cleaner is applied undiluted at 99.9% using a pre-saturated polyester or knitted cleanroom wiper at a coverage ratio of 0.3–0.5 mL per 100 cm²; the addition ratio is 100 parts cleaner to 0 parts deionized water. Compliance is monitored under ISO 14644-1 Class 5 or Class 7 cleanroom conditions, with particle counts verified by a laser particle counter set to channels of 0.3 µm and 0.5 µm. The production process is a unidirectional wipe on a flat lamination fixture, immediately followed by a dry wipe and a 10–20 s vacuum-assisted drying dwell before adhesive deposition. Terminal finished product types include smartphone OLED displays, automotive centre-stack displays, and wearable AMOLED modules. The operational boundary is the evaporation rate at the display edge; excessive solvent volume can wick into the polarizer edge and cause edge mura, so the wiper must be damp, not saturated, and the lot is inspected under crossed polarizers after lamination.
On rework benches that handle conformal-coated printed circuit assemblies, cured acrylic and urethane coatings over soldered components are softened locally with a 99.9% isopropyl alcohol cleaner before mechanical removal; the solvent is used undiluted at 100 parts product to 0 parts deionized water, applied at 0.5–1.0 mL per 25 cm² of coating surface. The rework procedure follows IPC-7711/21 for coating removal and replacement, while the replacement coating is qualified to IPC-CC-830B and final inspection is performed to IPC-A-610H Class 3 criteria. The production sequence consists of a solvent-saturated polyurethane swab held on the coating for 30–60 s, followed by non-metallic abrasion to lift the softened coating; the area is then wiped with a dry swab to remove suspended coating particles and dissolved activators. Terminal finished product types include reworked automotive engine control modules, avionics line-replaceable units, and industrial motor drives. The operational boundary is that cured silicone coatings are not dissolved by isopropyl alcohol and must be removed primarily by mechanical peeling; published data for this specific configuration is limited, so solvent-assisted adhesion reduction is validated on a first-article basis. The cleaned area is released only when the wiped-surface ionic contamination, sampled by 10 mL of 18.2 MΩ·cm deionized water extraction, is below 1.56 µg/cm² sodium chloride equivalence, thereby preventing field corrosion from entrapped rework residues.
Competitive MG Chemicals 99.9% Isopropyl Alcohol Electronics Cleaner prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618136850665 or mail to sales4@ascent-chem.com.
We will respond to you as soon as possible.
Tel: +8618136850665
Email: sales4@ascent-chem.com
Flexible payment, competitive price, premium service - Inquire now!
MG Chemicals 99.9% Isopropyl Alcohol Electronics Cleaner, supplied under part numbers 824-1L, 824-4L, 824-20L, and 824-450G, is a high-purity secondary process solvent based on isopropanol, CAS 67-63-0. The manufacturer-specified minimum purity is 99.9%, with water content controlled to ≤0.1% by weight. The product is intended for removal of rosin-based flux residues, light machine oils, handling films, dust, and ionic contamination from printed circuit assemblies, surface-mount stencils, optical fiber terminations, and metal contacts. In production and rework environments, application occurs by lint-free wipe, aerosol spray, trigger-pump dispenser, or ultrasonic immersion. The formulation differs from pharmaceutical-grade 70% isopropanol primarily in the reduced water fraction, which shortens room-temperature drying and lowers post-evaporation ionic residue on water-sensitive substrates.
At 101.3 kPa, the reported boiling point is 82.5 °C; the closed-cup flash point is 12 °C; vapor pressure is approximately 4.4 kPa at 20 °C; and liquid density is approximately 0.786 g/cm³ at 20 °C. The lower flammable limit of isopropanol in air is 2.0% by volume and the upper flammable limit is 12.7% by volume at 25 °C. The solvent is hygroscopic, and open containers in ambient air above 60% relative humidity absorb water, gradually approaching the isopropanol-water azeotrope near 87.7% isopropanol by mass. For high-purity rinse applications, bulk liquid should be held in closed HDPE or stainless steel containers, and dispensing should use dry-air or nitrogen blanketing when ambient humidity exceeds 60% RH. Incoming verification may be performed against ASTM D770, with lot-specific purity and water content reported on the certificate of analysis.
| Property | Nominal value | Measurement condition / method |
|---|---|---|
| Isopropanol purity | ≥99.9% | Gas chromatography, supplier CoA |
| Water content | ≤0.1% | Karl Fischer titration |
| Density | 0.786 g/cm³ at 20 °C | ASTM D4052 |
| Boiling point | 82.5 °C at 101.3 kPa | Reference data |
| Closed-cup flash point | 12 °C | ASTM D56 |
| Vapor pressure | 4.4 kPa at 20 °C | Reference data |
| Lower flammable limit in air | 2.0% at 25 °C | Reference data |
| Upper flammable limit in air | 12.7% at 25 °C | Reference data |
The 824-1L and 824-4L HDPE bottles are intended for manual dispensing and decanting into cleaning tools. The 824-20L pail is intended for bulk reservoirs in automated stencil cleaners and should be transferred using a grounded pump. The 824-450G aerosol is intended for spot cleaning and should not be used in ultrasonic baths or immersion processes. Ultrasonic immersion for bench-scale cleaning is generally performed at 40 kHz and 25–30 °C for 3–5 minutes in a covered, explosion-rated bath. Manual wipe cleaning of gold-edge connectors uses low-lint polyester swabs saturated with 0.1–0.2 mL of solvent per 10 cm², followed by a fresh solvent rinse and immediate drying with ionized air at 0.2–0.4 MPa. The material is not a corrosion inhibitor and does not leave a protective film; therefore, parts requiring temporary contact protection after cleaning must be treated with an additional protective coating or dry-film lubricant.
For printed circuit assemblies that must meet ionic cleanliness criteria before conformal coating or final inspection, the solvent is validated through the post-clean test rather than through purity alone. Resistivity of solvent extract is measured according to IPC-TM-650 method 2.3.25, and surface insulation resistance is evaluated according to IPC-TM-650 method 2.6.3.3. Under IPC J-STD-001, the default acceptance limit for high-reliability hardware is 1.56 µg/cm² sodium chloride equivalence. The 99.9% isopropanol product functions as a final rinse and carrier; it does not saponify water-soluble flux residues, nor does it neutralize acidic activators. Mechanical action from a wipe, brush, or ultrasonic field is required to suspend rosin and no-clean flux solids. The reduced water content of ≤0.1% minimizes the risk of leaving ion-bearing water films after evaporation, but heavy ionic films from activated water-wash flux require an aqueous cleaner and deionized water rinse rather than isopropanol alone. Ion chromatography per IPC-TM-650 method 2.3.28.1 may be used when specific ionic species such as chloride, sulfate, or weak organic acids must be quantified.
Because the closed-cup flash point is 12 °C, isopropanol vapor can form flammable mixtures with air at normal bench temperatures. Local exhaust ventilation should maintain vapor concentration below 25% of the lower flammable limit, and ultrasonic baths must be rated for flammable solvents with a temperature interlock set below 35 °C. The 824-450G aerosol package requires grounding and bonding of the work surface and applicator, and electrical equipment within the operating area must satisfy NFPA 70 hazardous-location classification or an equivalent regional code. Manual benchtop spray application is typically limited to bursts of 1–3 seconds at 15–25 cm from the substrate to reduce evaporative cooling and water condensation. Wipe application should use low-lint polyester or nonwoven wipes and should avoid saturated towels left uncovered; the evaporation rate at 20 °C can create a localized flammable vapor pocket in stagnant air. Storage must follow OSHA 1910.106 and NFPA 30 for Class IB flammable liquids, including the use of grounded metal cabinets and separation from oxidizers.
Substitution of 99.9% isopropanol for 70% aqueous isopropanol is justified when drying time, water penetration, and visible residue are process constraints. In a 70% mixture, water retards evaporation and may deposit ionic residues from tap or deionized water supplies; the 99.9% material evaporates more rapidly and leaves lower visible residue on glass and polished metal. Against hydrocarbon-blend flux removers, the isopropanol product is less aggressive on thermally polymerized no-clean residues but serves as a non-oily final rinse because it does not deposit high-boiling carrier oils. Against acetone, 99.9% isopropanol is generally less damaging to ABS and nylon, but it is not a universal plastic solvent. The solvent should not be used as a direct replacement for fluorinated or brominated vapor-degreasing solvents in equipment not designed for flammable liquids. In addition, the material is not effective on water-soluble flux residues after they have been reflowed to a highly crosslinked state; published data for this specific configuration is limited, and aqueous saponifier screening is advised for such residues.
Compatibility of 99.9% isopropanol with polymer enclosures and conformal coatings is a function of exposure time, molded-in stress, and temperature. Polycarbonate and acrylic are known to be susceptible to environmental stress cracking and local crazing when exposed to isopropanol, particularly at solvent-wetted edges, threaded bosses under torque, or solvent-entrapped seams. ABS and ABS/PC blends may soften or whiten under prolonged immersion. Natural rubber and some elastomers swell or extract plasticizers. Silicone, PTFE, HDPE, and Type 304 stainless steel are generally compatible. Conformal coatings such as acrylics and some urethanes may soften or lift with aggressive wipe pressure; polyurethane, silicone, and parylene coatings show higher resistance. For any mixed-material assembly, published data for this specific configuration is limited; a representative part should be exposed for 5–10 minutes using the same application method and then examined under 10x magnification for microcracking or coating adhesion loss. The solvent should not be used on energized equipment, and it should not be mixed with strong oxidizers such as concentrated nitric acid or hydrogen peroxide because exothermic decomposition can occur.