Products
| HS Code | 291564 |
| Chemical Name | Isopropyl Alcohol |
| Cas Number | 67-63-0 |
| Purity | 99.8% |
| Chemical Formula | C3H8O |
| Appearance | Clear, colorless liquid |
| Odor | Sharp, alcohol-like odor |
| Boiling Point | 82.5°C (180.5°F) |
| Flash Point | 12°C (53.6°F) closed cup |
| Specific Gravity | 0.786 at 20°C |
| Vapor Pressure | 33 mmHg at 20°C |
| Evaporation Rate | 2.8 (n-butyl acetate = 1) |
| Solubility In Water | Fully miscible |
As an accredited Techspray Isopropyl Alcohol (IPA) 99.8% Pure factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.
| Packing | One 16 oz (473 mL) spray bottle of Techspray Isopropyl Alcohol 99.8% Pure, with a trigger sprayer for cleaning and degreasing. |
| Container Loading (20′ FCL) | 20′ FCL: securely stowed, segregated, and restrained pallets of IPA drums/cases, with hazard-compliant loading for flammable liquid transport. |
| Shipping | This chemical ships via ground freight only due to hazmat regulations. It is packaged in leak-proof containers with proper labeling and safety documentation. No air or international shipping. Signature may be required upon delivery. Ensure storage away from heat and open flames. |
| Storage | Store in a tightly sealed original container in a cool, dry, well-ventilated area away from heat, sparks, open flames, and strong oxidizers. Keep the container upright to prevent leakage. Avoid excessive humidity, as IPA can absorb moisture. Ensure bonding and grounding when dispensing large quantities to prevent static discharge. |
| Shelf Life | Stable for 2–3 years unopened in original container, stored away from heat, ignition sources, and direct sunlight. |
Techspray 99.8% isopropanol, CAS 67-63-0, enters printed circuit board assembly cleaning as a defluxing fluid for Type 3 and Type 4 solder flux deposits on FR-4, polyimide, and insulated metal substrate boards. The closed-cup flash point of 11.7 °C measured under ASTM D56 and the autogenous boiling point of 82.45 °C restrict vapour-phase cleaning but permit spray-rinse and manual-wipe operations when the liquid temperature does not exceed 35 °C. A flat-spray manifold operating at 40–60 psi delivers the solvent to a conveyor travelling at 0.5 m/min; the board surface is maintained at least 3 °C above the ambient dew point because evaporative cooling from the high-vapour-pressure fluid can condense airborne moisture into the rinse film and trigger white ionic residue formation. In manual defluxing, the fluid is diluted to 80:20 (v/v) with 18 MΩ·cm deionized water when the residue contains water-soluble activators, amine hydrohalide salts, or polyethylene glycol tackants, while undiluted 99.8% solvent is retained for hydrophobic rosin and no-clean flux removal. Drying is carried out in a forced-air zone at 65 °C for 5 min, after which cleanliness is verified by resistivity of solvent extract per IPC-TM-650 2.3.25, using a 10 μS/cm acceptance threshold for high-reliability hardware. Subsequent qualification is clamped to IPC J-STD-001G electrical cleaning requirements, IPC-A-610H visual acceptance criteria, and surface insulation resistance per IPC-TM-650 2.6.3.7. Terminal assemblies include automotive engine-control modules, industrial power PCBs, high-density interconnect boards with 0.4 mm pitch ball-grid arrays, and IoT sensor nodes that require low ionic contamination after rework.
Automated stencil cleaning on the same line meters 0.8–1.2 mL of 99.8% isopropanol per printer cycle through the under-stencil wipe mechanism; the roll stock advances 20 mm per wipe and a vacuum plenum held at −0.5 bar pulls solder paste from laser-cut and electroformed apertures. A separate ultrasonic bath operating at 40 kHz and 0.4 W/cm² for 3–5 min removes paste from blind apertures and micro-BGA pads. Production-shift observations indicate that extended immersion beyond 10 min can initiate solder mask edge attack at scribe lines on low-Tg FR-4, so the bath timer is interlocked at 5 min and solvent is changed when the IPA assay drops below 96% due to flux loading. Wetted surfaces are limited to PTFE, EPDM, and 316 stainless steel; polycarbonate sight glass and natural nitrile seals are excluded because stress crazing and swelling can appear within 24 h of continuous contact. Headspace monitoring for the solvent is set to alarm at 25% of the lower explosive limit of 2.0% by volume, and the extraction system maintains a face velocity of 1.2 m/s across open spray zones. The solvent is not added to saponified azeotropic wash tanks because its low autogenous flash point creates a fire hazard in the unsealed prewash and drag-out stages.
The difference between a 99.8% neat rinse and an 80:20 dilution is not managed by intuition but by failure data: neat IPA removes hydrophobic rosin rapidly but leaves chloride-containing activators as a thin hygroscopic film, while the aqueous blend removes chlorides but can swell paper laminate edges and extend the drying time. Therefore a two-step sequence is used on mixed-residue boards: first the 80:20 mixture is applied by brush at 10 mL per 100 cm² board area, then a neat 99.8% final rinse reduces surface water and prevents etch-out at exposed copper. For assemblies with micro-coaxial connectors and polymethyl methacrylate lenses, local exposure is limited to 5 s because 99.8% IPA generates microcrazing in stressed PMMA. These process boundaries are recorded in the work instruction; no substitution of lower-grade IPA is permitted because water above 0.5% introduces evaporative striations on solder mask and changes the cleaning rate in the production spray chamber.
Regulatory reference for the material in medical device assembly is established through residual-solvent classification in ICH Q3C, which assigns a Class 3 acceptable daily exposure of 50 mg/day, and through cleaning documentation under 21 CFR 211.67 for equipment of pharmaceutical and combination-product processing. The 99.8% fluid is used to remove cutting oils, sulfate-based lubricants, silicone mold release, and protein soils from 316L stainless steel fixtures, polycarbonate housings, PVC catheter shafts, and thermoset silicone components. Neat solvent is sprayed at 10–15 mL/m² or applied to a low-lint polyester-cellulose wiper at 30–40% saturation by weight; wiping strokes are unidirectional at 25 cm/s and the wiper is folded after each stroke to avoid transfer of plating salts back to the device surface. For bioburden reduction, a 70:30 (v/v) isopropanol-to-sterile water mixture is used rather than the 99.8% concentrate, because the water fraction is necessary to denature microbial proteins and reduce clumping of cell debris that would otherwise shield organisms from chemical contact. The cleaned device is rinsed with USP purified water, dried in a Class ISO 7 cleanroom with HEPA-filtered air at 0.45 m/s face velocity, and tested for residual solvent by headspace GC with an acceptance limit of 10 µg/cm² for prolonged patient-contact surfaces.
Cleaning validation uses coupons inoculated with 10 µL/cm² of thermal cutting oil or bovine serum albumin, followed by extraction in 99.8% isopropanol and gravimetric or total organic carbon determination. Recovery of not less than 80% of the applied challenge is considered acceptable for non-critical surface preparation; for blood-contacting devices, the limit is tightened to 90% recovery and the rinse is sampled for particulate matter under USP 788. Terminal products include peripheral IV catheters, guidewire coils, insulin pump housings, electrosurgical handpiece return electrodes, and CPAP humidifier reservoirs. The boundary is explicit: 99.8% isopropanol is not labeled as a sterilant or sporicidal agent; terminal disinfection is completed with a separate validated cycle, such as sterile 70% IPA or hydrogen peroxide vapour, when the device cannot tolerate heat sterilization.
In fiber-optic connector termination, a droplet of 99.8% isopropanol applied to an ISO 18903 compliant nonwoven swab removes skin lipids, handling oils, and fiber coating debris from 1.25 mm zirconia ferrules and 125 μm silica cladding. The fluid is used undiluted for final cleaning when single-mode return loss must be better than −50 dB; it is diluted to 90:10 (v/v) with 18 MΩ·cm deionized water when inorganic dust from the production floor requires a thin aqueous film to lift particles without leaving a water mark. Cassette cleaners meter 5–8 mL per port, and the wipe stroke moves across the ferrule tip at 10–30 mm/s in one direction only to avoid cycling the removed debris through the core region. The end-face is immediately inspected at 200× or 400× magnification per IEC 61300-3-35, with a scratch and defect pass grade of 4 or better for single-mode interconnects. Bench temperature is maintained at 20–23 °C and relative humidity between 40% and 60% to slow evaporation and prevent striations on polished zirconia surfaces.
For female alignment sleeves and MT ferrules, a foam-tipped swab pre-saturated with 0.1 mL of 99.8% isopropanol is inserted and rotated only two full turns; excessive rotation compresses the foam and pushes particle agglomerates into the alignment feature. After cleaning, the port is inspected with a hand-held probe at 400× and insertion-loss data are collected on a 1310 nm single-mode test set to confirm that the cleaning process does not degrade interfacial polish. The process boundary for thick hydrocarbon buffer gels is documented: 99.8% isopropanol may not fully solvate some gel formulations, so a two-step cleanup using a fluorinated co-solvent followed by the IPA rinse is specified for high-force insertion ports. Published data for this specific configuration is limited; end-face inspection after cleaning remains the controlling acceptance method. Terminal products include LC and MPO patch cords, OTDR test leads, planar lightwave splitters, and fiber Bragg grating strain sensors.
Nitrocellulose and polyamide flexographic inks for flexible packaging incorporate 99.8% isopropanol at 5–20 wt% of the press-ready formulation. In a typical varnish containing 8–12 wt% nitrocellulose solids, increasing the IPA loading from 5% to 20% reduces press viscosity from approximately 35 s to 18 s on a Zahn cup #2 at 25 °C. The alcohol functions as a retarder and resin-compatibilizer, not merely as a diluent; at press-hall temperatures of 10–15 °C, its presence suppresses precipitation of polyamide resins that would otherwise form as surface skin on the ink tray and transfer roller. The press-ready fluid is delivered through a 200-line anilox roll with 3.5 BCM cell volume, and chambered doctor blade pressure is set at 2–4 bar to maintain a stable ink film with no streaking on the substrate. Drying tunnel setpoint is held at 50–70 °C with air velocity 10–15 m/s; excessive IPA retention in biaxially oriented polypropylene raises final residual solvent above 5 mg/m² unless the solvent package is rebalanced with ethyl acetate or n-propyl acetate.
The high-purity IPA grade enters the ink varnish after letdown in a closed high-shear mixer running at 1,500–3,000 rpm; it is added after the nitrocellulose base is fully wetted to prevent localized resin precipitation at the addition port. Press operators set the viscosity target each shift with a Zahn cup, adding IPA in 1 wt% increments to adjust a viscosity drift caused by solvent evaporation; the same IPA addition shifts the drying-rate curve and solvent-retention profile, so the drying tunnel temperature is adjusted only after a print trial is evaluated for blocking. Compliance for printed food-contact layers references REACH (EC) 1907/2006 and Swiss Ordinance 817.023.21 Annex 6 for low-migration inks. Terminal products include biaxially oriented polypropylene snack wrappers, cold-seal lids, shrink sleeve labels, and polyethylene bread bags. The process boundary is set by plate swell and print definition: above 20 wt% IPA in a photopolymer plate press, dot shoulder swelling reduces highlight dot transfer and raises minimum printable dot size above 75 µm on flexible substrates.
Before polyurethane adhesives and pressure-sensitive structural tapes are applied to painted or powder-coated automotive steel and aluminium, a 99.8% isopropanol wipe removes silicone mold release, anti-corrosion oil, and handling residues. A 70:30 (v/v) isopropanol/DI water blend is used on single-stage and basecoat/clearcoat finishes to reduce solvent lift and gloss loss, while neat IPA is retained for bare anodized aluminium or 316 stainless steel surfaces. Robotic end-effectors meter the fluid at 20–30 mL/m², apply 1.8–2.2 N of normal force, and traverse at 50 mm/s with 50% overlapping passes. The wiped area flashes dry for 30–60 s; adhesive or structural tape is applied within 60 min to avoid recontamination by ambient siloxanes and blown-in dirt.
Adhesion characterization is performed on sacrificial coupons using ASTM D3359-17 cross-cut adhesion after solvent wiping and ASTM D3330 peel testing for pressure-sensitive tapes. Destructive bond evaluation is performed at 23 °C and 50% relative humidity, with a production acceptance threshold of 90% cohesive failure within the adhesive layer rather than at the substrate interface. The boundary condition is known: 99.8% isopropanol can soften alkyd enamel and certain acrylic lacquer systems, so a hidden-area rub test using 20 double wipes is required before the solvent is introduced onto a paint line. Terminal products include bonded roof spoilers, side-sill extensions, trailer panel adhesives, and composite door panels. A lower-purity IPA is not substituted because the water fraction above 0.5% delays flash-off and increases the risk of adhesion loss on water-sensitive primers.
In display lamination lines, 99.8% isopropanol is employed as a final wipe on indium tin oxide coated glass and polycarbonate optical films before optically clear adhesive bonding. An 80:20 (v/v) isopropanol/DI water solution is preferred for glass to reduce static charge and lift fine glass particulates, while neat 99.8% IPA is restricted to polycarbonate films only when evaporation time is kept below 5 s because longer exposure risks microcrazing at stress-concentrating film edges. The process specification includes an alpha-clean roller charged at 10 kV to remove residual dust, low-lint polyester wipes saturated at 40%, and lamination within 5 min to prevent fallout. Compliance is tied to ISO 14644-1 Class 7 cleanroom conditions and REACH SVHC documentation. Terminal products include smartphone LCD modules, tablet touch-film planarizer layers, and automotive center-stack displays. Published data for this specific configuration is limited; visual inspection under 1000 lux and peel adhesion testing per ASTM D6862-11 are used as the controlling production checks.
In analytical laboratories, 99.8% isopropanol is applied as a terminal rinse for glassware, syringes, and extraction vessels before EPA SW-846 8000 series organic analyses and ISO 6353-2 reagent-grade procedures. A controlled sequence uses 5–10 mL of the solvent per 40 mL vial in three separate aliquots, followed by a final acetone or methylene chloride rinse when the instrument method includes volatile target compounds. Evaporation is performed under nitrogen at 40 °C and 0.5 bar with a flow rate of 2 L/min; the vials are then baked at 105 °C for 2 h to reduce residue below 0.1 µg/cm². The solvent is compatible with PTFE-lined closures and does not extract phthalate plasticizers from virgin borosilicate glass or polypropylene autosampler vials under these conditions. Terminal products include EPA 8270 semivolatile organic extract vials, LC-MS/MS autosampler vials, and gas chromatography sample vials. The documented limitation is chromatographic interference: if isopropanol is not completely removed, a residual peak can appear near ethanol in flame ionization detection and may coelute with C3 oxygenates in purge-and-trap methods; for those methods, the final rinse is replaced with n-propanol or acetone to eliminate the interference.
Competitive Techspray Isopropyl Alcohol (IPA) 99.8% Pure prices that fit your budget—flexible terms and customized quotes for every order.
For samples, pricing, or more information, please contact us at +8618136850665 or mail to sales4@ascent-chem.com.
We will respond to you as soon as possible.
Tel: +8618136850665
Email: sales4@ascent-chem.com
Flexible payment, competitive price, premium service - Inquire now!
Techspray Isopropyl Alcohol (IPA) 99.8% Pure is a high-purity secondary alcohol used as a precision cleaning solvent, residue remover, and surface-drying agent. The product identity is CAS 67-63-0, with a minimum assay of 99.8% isopropanol by gas chromatography. The residual fraction is predominantly water, with a specification that water content determined by Karl Fischer titration under ASTM E203 does not exceed 0.2% by weight. Typical physical properties include a closed-cup flash point of 11.7 °C, a normal boiling point of 82.5 °C, and a density of approximately 0.785 g/cm³ at 20 °C. Model designations for Techspray IPA 99.8% are assigned by packaging configuration, container closure, and lot traceability rather than by chemical profile; the same solvent is distributed in bulk containers, trigger sprays, and controlled-pour bench-top formats. All use configurations are subject to flammable-liquid handling controls under 29 CFR 1910.106, including grounded transfer and local exhaust ventilation where open containers are used.
The 0.8% difference in nominal assay is operationally significant in open-container cleaning where water is the main source of slow drying and ionic residue retention. A 99% industrial IPA may contain up to 1.0% water by mass and nonvolatile contaminants that remain at the drying front after the alcohol evaporates. In the 99.8% grade, the water specification is reduced to 0.2% or lower, which shortens the evaporative dry time on hydrophobic solder-mask surfaces and decreases the probability of water-promoted white residue around fine-pitch surface-mount packages. The effect is observable in ionic contamination testing using IPC TM-650 2.3.25 with a 75% isopropanol/25% deionized water extraction; however, board values also depend on wipe linting, extraction time, flux chemistry, and soldering thermal history.
At atmospheric pressure, the isopropanol-water system forms an azeotrope near 87.7 wt% isopropanol and 80.4 °C. Ordinary fractional distillation cannot reach 99.8% purity from commodity streams; the product is therefore dehydrated beyond the azeotropic limit. This distinction matters during lot review because the assay should be confirmed by the supplier’s gas-chromatographic certificate rather than inferred from distillation range alone: the boiling-point shift in the final 1–2% water range is small enough to be masked by normal process variation.
In printed circuit board assembly, the solvent is used in benchtop wiping and stencil-cleaning operations where rosin-based pastes and no-clean flux residues are removed before conformal coating. A typical manual process dispenses 10–15 mL per 30 cm × 30 cm stencil area with a low-lint polyester wipe. The alcohol dissolves polar activators and reduces the mechanical force required to clear apertures, while the reduced water content limits spreading of partially dissolved activators into fine-pitch openings. Ionic cleanliness is assessed by IPC TM-650 2.3.25 or by resistivity of solvent extract, but no single wipe procedure can guarantee conformance unless fluid volume, wipe pressure, and pass count are controlled. On boards containing unsealed ceramic resistors, ink-jet legends, or solvent-sensitive membrane components, published data for this specific configuration is limited; first-article compatibility testing should be performed before production release. For fiber-optic connector end-faces, residue after drying is the main defect mechanism. The 99.8% product is applied with sealed foam-tipped swabs or optical-grade wipes because water above 0.2% can deposit mineral traces from the wipe itself during the final evaporation stage. A single-pass drying time on zirconia ferrules is typically below 10 s at 20–22 °C; however, at ambient humidity above 60% RH, condensation cooling during evaporation can locally increase surface water and slow the visual disappearance of fluid. End-face inspection under 200× microscope with coaxial illumination is the standard control method. If faster drying is required, acetone is not automatically substituted because its higher vapor pressure is accompanied by a lower flash point and greater sensitivity to water condensation on optics.Water is the slowest-evaporating component in the product. On low-energy surfaces such as solder mask, polyimide film, and plasma-treated polytetrafluoroethylene, the alcohol phase evaporates rapidly while water may persist in microdroplets that redeposit extracted ionic species. A 0.2% water specification reduces the mass of slow-evaporating liquid per unit area to less than 2 mg for a 1 mL dispense, assuming no atmospheric uptake. This is below the visual residue threshold for many precision surfaces, but it is not a universal cleanliness limit. Drying time can be determined gravimetrically using a balance with 0.1 mg readability under controlled airflow of 0.3–0.5 m/s. Cleanroom wiping should use non-linting polyester or nylon wipes rather than cellulose-based materials, because cellulosic particles and bound extractables dominate particle counts measured by IEST-RP-CC004.
The solvent is hygroscopic in open containers. At ambient humidity above 60% RH, water vapor uptake can increase the effective water content of the liquid during use, even if the bulk lot began at 0.2% or lower. This limitation is more severe in cold ultrasonic tanks because condensation forms on the liquid surface and container walls. To maintain the cleaning advantage of the high-purity grade, bulk containers should be sealed immediately after transfer, and wipe bottles should be fitted with one-way dispensing closures that limit headspace exchange. Published data for water uptake rates in this specific packaging configuration is limited; therefore, production records should include periodic Karl Fischer spot checks using ASTM E203 rather than relying solely on the original certificate of analysis.
Table 1 compares the product with lower-purity isopropanol, electronic-grade isopropanol, and acetone in properties relevant to precision cleaning. The values are typical general material data, not lot-specific certificate limits.
| Property | Techspray IPA 99.8% | Industrial 99% IPA | Electronic-grade 99.9% IPA | Acetone |
|---|---|---|---|---|
| Minimum assay | 99.8% | 99.0% | 99.9% | 99.5% |
| Water content | ≤0.2 wt% | ≤1.0 wt% | ≤0.1 wt% | ≤0.5 wt% |
| Closed-cup flash point | 11.7 °C | 11.7 °C | 11.7 °C | −17 °C |
| Normal boiling point | 82.5 °C | 82.5 °C | 82.5 °C | 56.1 °C |
| Density at 20 °C | 0.785 g/cm³ | 0.786 g/cm³ | 0.785 g/cm³ | 0.791 g/cm³ |
| Evaporation rate (n-butyl acetate = 1) | 2.8 | 2.8 | 2.8 | 5.6 |
| Surface tension at 20 °C | 21.7 mN/m | not typically specified | 21.7 mN/m | 23.3 mN/m |
| Kauri-butanol value | 68 | 68 | 68 | 76 |
The comparison indicates that the principal advantage of 99.8% over 99% is not solvency power, which is effectively equivalent, but reduced water mass in the final evaporation film. Compared with acetone, isopropanol has a higher flash point and a lower evaporation rate, making manual wiping easier to control. Acetone remains preferable where extremely rapid evaporation is required, but its higher Kauri-butanol value produces greater attack on some plastics and coatings. Electronic-grade 99.9% IPA further reduces water and metal-ion levels; however, published data for measurable cleanliness improvement over 99.8% IPA in standard printed circuit board ionic contamination testing is limited. The difference becomes more relevant in wafer fabrication, laser optical assemblies, and biomedical surfaces where trace metal deposition is controlled to part-per-billion levels.
A bench-top ultrasonic bath operating at 40 kHz and 20–30 °C can be used for removing flux residues from assembled boards, but the flammable character of isopropanol requires the bath to be placed in a ventilated enclosure with local exhaust and no exposed electrical contacts. The liquid temperature must not be raised toward the flash point; even at bath temperatures below 11.7 °C, the vapor can form ignitable mixtures if headspace accumulates. In practice, ultrasonic cleaning with isopropanol is often limited to short cycles of 2–5 min, after which the boards are transferred to a second rinse of the same solvent to remove loosened particles. The evaporation rate in an open bath is high enough that solvent consumption can exceed 0.5 L/m² of processed board area per shift; this is not a fixed limit but a production-scale observation dependent on workload, tank geometry, and ventilation rate.
Polycarbonate housings, acrylic windows, and some acrylonitrile-butadiene-styrene blends are susceptible to stress cracking when contacted with isopropanol under load. ASTM D543 immersion or patch testing for visual crazing and tensile reduction should be performed before replacing a hydrocarbon cleaner with IPA. Polytetrafluoroethylene, fluoropolymer, stainless steel, and glass equipment are compatible in typical room-temperature use. Aluminum parts may show no general corrosion in dry IPA, but water absorption above 0.2% can promote localized etching if chlorides are already present. The solvent should not be assumed to provide corrosion inhibition for metal assemblies.
The product is subject to the following standards and regulatory classifications when incorporated into a controlled manufacturing process. The matrix is not exhaustive; current lot documentation and application-specific regulatory review remain necessary.
| Standard or regulation | Designation or method | Relevance to the product | Product position |
|---|---|---|---|
| ASTM D770 | Standard Specification for Isopropyl Alcohol | Assay, acidity, water, distillation range, and nonvolatile residue control | Used as a purchasing-grade framework when specified; not all limits are reported on commercial technical data sheets |
| ASTM E203 | Karl Fischer water titration | Water content ≤0.2 wt% | Specified for this product |
| ASTM D4052 | Density and relative density by digital density meter | Typical density 0.785 g/cm³ at 20 °C | Reported on lot certificate where required |
| ASTM D1078 | Distillation range of volatile organic liquids | Normal boiling point 82.5 °C | Reported only when the purchasing specification requires distillation data |
| REACH Regulation (EC) No 1907/2006 | Substance registration and downstream use conditions | Isopropanol is a registered substance in the European Union | Downstream users must apply the use conditions in the safety data sheet |
| RoHS Directive 2011/65/EU | Restricted substances in electrical and electronic equipment | No intentionally added lead, mercury, cadmium, hexavalent chromium, PBB, or PBDE | Chemical declaration supports article-level compliance; the solvent itself is not an article |
| OSHA 29 CFR 1910.106 | Flammable liquid handling | Closed-cup flash point 11.7 °C | Requires grounded transfer and ventilated storage |
| 21 CFR 178.1010 | Sanitizing solutions for food-contact surfaces | Isopropanol is recognized when used within regulatory limits | The product should not be considered a food-grade direct additive; food-contact use must be qualified separately |