Ascent Petrochem Holdings Co., Limited
Products
Products

Products

Isopropyl Alcohol, Electronic Grade, 99.5%

    • Product Name: Isopropyl Alcohol, Electronic Grade, 99.5%
    • Factroy Site: Binhai New Area, Tianjin, China
    • Price Inquiry: sales4@ascent-chem.com
    • Manufacturer: Ascent Petrochem Holdings Co., Limited
    • CONTACT NOW
    Specifications
    HS Code 329972
    Chemical Formula C3H8O
    Cas Number 67-63-0
    Molecular Weight 60.10 g/mol
    Appearance Clear colorless liquid
    Purity 99.5%
    Boiling Point 82.5 °C
    Melting Point -89.5 °C
    Flash Point 11.7 °C
    Density 0.786 g/cm3 at 20 °C
    Solubility Miscible with water
    Refractive Index 1.377 at 20 °C
    Vapor Pressure 33 mmHg at 20 °C
    Water Content ≤ 0.1%
    Resistivity > 10 MΩ-cm

    As an accredited Isopropyl Alcohol, Electronic Grade, 99.5% factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing Packaged in a 1 L amber glass bottle with an airtight seal, ensuring high purity for electronic-grade cleaning applications.
    Container Loading (20′ FCL) 20' FCL: secure drums/totes, upright, with proper segregation. Ensure ventilation, grounding, and hazard labeling for flammable electronic-grade isopropyl alcohol.
    Shipping Isopropyl Alcohol, Electronic Grade, 99.5%, ships as UN1219, Isopropanol, Class 3, Packing Group II. It requires approved containers, usually steel drums or IBCs, with flammable liquid labels. Keep away from oxidizers and ignition sources. Transport by ground or sea; air shipment is heavily restricted. Complete shipping documentation and emergency response information are mandatory.
    Storage Store in a cool, dry, well-ventilated area away from heat, sparks, open flames, and direct sunlight. Keep the container tightly sealed to prevent contamination and moisture absorption, preserving electronic-grade purity. Use grounded containers and bonding when dispensing. Store separately from oxidizing agents, acids, and reactive metals. Follow local flammable liquid storage regulations.
    Shelf Life Shelf life is typically 3 years if unopened, stored in original container, tightly sealed, away from heat and ignition sources.
    Application of Isopropyl Alcohol, Electronic Grade, 99.5%

    300 mm copper/low-k logic lines and advanced NAND flash fabs treat 99.5% electronic-grade IPA as a high-purity solvent for post-ash residue removal, wafer cleaning, and Marangoni drying. The receiving specification is aligned to SEMI C41 and ASTM D770; the certificate of analysis includes assay by GC-FID at ≥99.5 wt%, water at ≤0.10 wt% by ASTM D1364, nonvolatile residue at ≤5 ppm by ASTM D1353, chloride at ≤0.2 ppm by ASTM D512, acidity at ≤0.002 wt% as acetic acid by ASTM D1613, and distillation range between 82.0 °C and 83.0 °C by ASTM D1078. Point-of-use distribution uses fluoropolymer wetted surfaces and 0.05 μm membrane filtration; the liquid is blanketed with nitrogen because open reservoirs absorb atmospheric moisture and alter the water-solvent balance. In the Marangoni dryer, the solvent is not used as a bulk liquid rinse. It is vaporized into the carrier gas so that the surface-tension gradient between IPA at 21.7 mN/m and water at 72.8 mN/m at 20 °C displaces the final aqueous film from high-aspect-ratio gate and trench structures. The process window is bounded on one side by flammability: the lower flammability limit is 2.0 vol% in air, and the closed-cup flash point is 12 °C under ASTM D56. It is bounded on the other side by moisture collapse: water above 0.10 wt% in the liquid phase reduces the Marangoni gradient and produces watermark defects on exposed copper and cobalt. Published data for exact vapor-phase injection setpoints in production Marangoni chambers is limited because these settings are configured by the wet-bench OEM and adjusted through defectivity partitioning; however, the measurable solvent-release parameters are the CoA limits and the point-of-use particle count. The terminal product is a dried patterned wafer entering gate stack deposition, Cu seed deposition, or post-CMP metrology.

    The table below lists the front-end CoA limits that are cross-checked at the fab materials-intake laboratory.

    Release parameterTypical limit for front-end useTest method
    IPA assay≥99.5 wt%ASTM D770 GC-FID
    Water≤0.10 wt%ASTM D1364
    Nonvolatile residue≤5 ppmASTM D1353
    Chloride≤0.2 ppmASTM D512
    Acidity≤0.002 wt% as acetic acidASTM D1613
    Distillation range82.0–83.0 °CASTM D1078

    What Threshold of Moisture Ingress Converts Edge Bead Removal IPA into a Silicon Native Oxide Risk?

    During photoresist edge bead removal on lithographic coater tracks, the solvent ratio is 100:0: 99.5% electronic-grade IPA is dispensed neat through the EBR nozzle at the wafer edge and, on some tracks, at the backside edge-exclusion zone. There is no water dilution because water in the edge-bead solvent can create residual scum after soft bake. The in-use moisture threshold is ≤0.10 wt%; above this, the solvent leaves a thin aqueous film on exposed silicon and promotes native oxide formation before the develop step. The day tank is sealed, blanketed with N2, and sampled by Karl Fischer titration under ASTM D1364; top-up is not performed from open containers. The track exhaust is designed to keep vapour concentration below the 2.0 vol% lower flammability limit, and the enclosed dispense system meets SEMI S2 and SEMI S8. Wetted components use PTFE, ETFE, and electropolished stainless steel; natural rubber and butyl rubber seals are excluded because they swell and release extractables. The terminal product is a photoresist-coated wafer with controlled edge exclusion and no solvent-induced frontside residue.

    Low-Flash-Point Stencil Cleaning in Enclosed Under-Stencil Wipe Modules

    High-volume SMT stencil printing cells use 99.5% electronic-grade IPA undiluted in enclosed under-stencil wipe modules for solder paste residue removal. The solvent ratio is 100% IPA for type 3–type 5 solder paste residues; a 70:30 IPA–deionised water mixture is limited to manual wiping of uncured no-clean flux on benchtops, and only when the board is immediately dried with filtered air. The wipe module is grounded, fitted with a sealed solvent reservoir, and operated under negative-pressure exhaust; the closed-cup flash point is 12 °C under ASTM D56. Stencil aperture cleanliness is verified by solder paste release performance and by inspection under IPC J-STD-001 soldered assembly criteria; residue acceptance follows IPC-CH-65B or an ion-chromatography threshold specified by the electronics assembler. The terminal product is a stencil-ready printed circuit board assembly with paste deposits meeting IPC-7525 stencil design tolerances.

    Fiber optic connector end-face production lines operating to IEC 61300-3-35 acceptance criteria use 99.5% electronic-grade IPA as the final cleaning solvent. The solvent ratio is 100:0; water or aqueous detergent is not used because residual moisture on a ferrule can form a contaminant film after connector mating. The process applies the solvent through a sealed polyester-tipped cleaning stick or a microfiber reel inside an ISO 14644-1 Class 5 enclosure. IPA removes draw tower particulate, buffering gel, and adhesive outgassing from single-mode ceramic ferrules without leaving ionic residue above the IEC 61300-3-35 core/cladding scrutiny requirement. A 400× interferometer inspects end-face scratches after cleaning; any solvent remaining in the alignment sleeve is removed with a filtered air puff. The terminal product is a terminated fiber optic connector assembly ready for patch cord overmolding or ceramic ferrule final assembly.

    When 99.5% IPA Replaces HCFC-225 in Precision Optics Flushing

    In precision optics assembly, 99.5% electronic-grade IPA replaces HCFC-225 and n-propyl bromide for flushing lapping compounds, wax, and cement residues from coated lens surfaces. The cleaning ratio is 100:0 solvent; no water is added because a water phase can alter selective dissolution of multilayer antireflection coatings and can wick into porous inorganic coatings. The process uses an explosion-proof ultrasonic bath fitted with 0.45 μm particulate filters; the bath temperature is held below 25 °C, and the liquid is recirculated through a fluoropolymer cartridge. Coated optics are flushed for the shortest interval required to meet ISO 10110-7 surface imperfection inspection after drying. Acrylic and polycarbonate components are excluded from the bath because IPA stress cracking occurs; glass, fused silica, protected metal coatings, and most metal oxide interference films are accepted. The terminal product is a coated lens element or prism ready for alignment and mechanical mounting.

    Limiting Polyimide Swelling During IPA Edge Wipe on LCD Cells

    LCD cell assembly lines use 99.5% electronic-grade IPA for glass edge cleaning, sealant residue removal, and pre-polarizer lamination wipe. The solvent is applied neat at 100% to cleanroom wipers that meet IEST-RP-CC004.3 extractables limits. The dwell time is controlled to the shortest window that removes edge sealant residue without contacting the polyimide-coated pixel area; wiper passes are unidirectional to prevent recontamination. Direct contact with polyimide alignment layers is avoided because solvent ingress can shift azimuthal anchoring energy and produce mura after LC filling. The work is performed in an ISO 14644-1 Class 5 cleanroom with local exhaust because the flash point is 12 °C under ASTM D56. The terminal product is a display cell ready for liquid crystal filling, ODF seal curing, or polarizer lamination.

    Free Quote

    Competitive Isopropyl Alcohol, Electronic Grade, 99.5% prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please contact us at +8618136850665 or mail to sales4@ascent-chem.com.

    We will respond to you as soon as possible.

    Tel: +8618136850665

    Email: sales4@ascent-chem.com

    Inquiry

    Get Free Quote of Ascent Petrochem Holdings Co., Limited

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance
    More Introduction

    Isopropyl Alcohol, Electronic Grade, 99.5%, CAS 67-63-0, is a controlled-impurity aliphatic secondary alcohol supplied for precision cleaning, rinsing, and drying in printed circuit board assembly, semiconductor equipment maintenance, hybrid microcircuit fabrication, and optical coating preparation. The grade is defined by assay at ≥99.5 wt%, water at ≤0.2 wt%, non-volatile residue at ≤5 ppm, acidity at ≤0.002 meq/g, chloride at ≤1 ppm, sulfate at ≤1 ppm, and specified trace metal limits. The bulk liquid has a normal boiling point of 82.4 °C, a closed-cup flash point of 11.7 °C, a vapor pressure of 4.4 kPa at 20 °C, and a lower flammable limit of 2.0% by volume. The material is filtered through 0.2 µm or 0.1 µm media during filling, and common package formats are 1 L, 4 L, and 20 L high-density polyethylene containers, 200 L stainless steel drums, and 208 L fluoropolymer-lined drums. No universal model designation exists; the product is identified by CAS number, assay, electronic-grade designation, and supplier lot documentation. Because the product is not anhydrous, the 2000 ppm water ceiling is the primary operational boundary distinguishing it from 99.9% anhydrous electronic grades and from technical grades with water limits near 1.0 wt%.

    How Do Water, NVR, and Ionic Cleanliness Distinguish 99.5% Electronic Grade from USP and Technical IPA?

    The differentiation between 99.5% electronic-grade isopropyl alcohol and USP/NF, ACS reagent, or technical-grade IPA depends on water content, post-evaporation residue, acidity, trace chloride, and particle burden. ASTM D770-21 provides assay and impurity test methods for isopropyl alcohol, but electronic-grade purchase specifications add particle count and lot-specific trace metal limits that are not found in ACS or USP monographs. The table below lists representative purchase limits for the four grades. ACS reagent material may have similar assay and water ceilings but is not generally supplied with a particle count below 25 particles/mL at 0.5 µm or with trace metal certification suitable for semiconductor support. USP/NF material is controlled for pharmaceutical excipient use but has a water limit that is commonly less stringent and no particle count requirement for microelectronic cleaning. Technical-grade material often contains higher aldehyde, ketone, and organic residue levels that appear as haze or elevated NVR after evaporation.

    Representative grade comparison for isopropyl alcohol, based on common purchase specifications
    ParameterElectronic grade 99.5%ACS reagentUSP/NFTechnicalTest method
    Assay (wt%)≥99.5≥99.5≥99.0≥98.0ASTM D770-21
    Water (wt%)≤0.2≤0.2≤0.5≤1.0ASTM E203
    Non-volatile residue (ppm)≤5≤10≤25≤100ASTM D1353
    Acidity (meq/g)≤0.002≤0.002Not specified≤0.01ASTM D1613
    Chloride (ppm)≤1≤1Not specified≤5ASTM D512

    Particle count control is a purchase specification rather than a grade monograph. In electronic cleaning, limits of ≤25 particles/mL at ≥0.5 µm are common, and values below 10 particles/mL are available from suppliers using cleanroom filtration and packaging. Anhydrous 99.9% electronic-grade IPA differs primarily in water content, typically ≤0.1 wt%, and may show NVR limits of ≤2 ppm. That anhydrous product is used where sub-10 nm semiconductor pattern collapse, watermark defects, or capillary-force drying effects must be avoided. The 99.5% product remains suitable for back-end assembly, stencil cleaning, tool maintenance, and optical cleaning where 2000 ppm water is tolerable and the higher cost of anhydrous product is not necessary.

    During solder paste stencil cleaning and misprinted board rework, 99.5% electronic-grade isopropyl alcohol is applied through pressurized spray or 40 kHz ultrasonic immersion to dissolve solder paste binders, rosins, and thin no-clean flux films before reflow. The 0.2 wt% water ceiling matters because excess water slows evaporation after cleaning and can raise ionic contamination measured by IPC-TM-650 Method 2.3.25 above the 1.56 µg NaCl equivalent/cm² reference threshold used in J-STD-001 cleanliness acceptance guidance. On dense surface-mount assemblies, incomplete drying in undersoldered gaps can leave conductive or hygroscopic films, so air-knife drying at 200–400 kPa with filtered compressed air is applied after solvent cleaning.

    In optical coating preparation, the NVR limit is more critical than water. A residue limit of ≤5 ppm is required before electron-beam or ion-assisted deposition on fused silica and borosilicate substrates, because post-evaporation films create scatter sites detectable by spectrophotometry across the 400–700 nm range. Cleaning with low-NVR isopropanol and low-shedding wipers, followed by dry nitrogen blow-off through a 0.45 µm filter at 200 kPa, removes organic films without leaving visible haze. In stencil screen printing, the product is used to clean squeegees, under-stencil wipers, and framed stencils. Point-of-use filtration at 0.2 µm prevents insoluble particles from embedding into stencil apertures. The 99.5% grade is acceptable in these uses when post-clean ionic contamination remains within process control limits; assemblies intended for high-voltage or high-impedance circuits may require the 99.9% anhydrous grade or a lower-NVR solvent.

    Vapor Degreasing, Ultrasonic Immersion, and Spin-Rinse Dryer Operating Windows

    Closed-loop vapor degreasers using 99.5% isopropyl alcohol operate with a boiling point of 82.4 °C and a closed-cup flash point of 11.7 °C. Flammable vapor control must be engineered below the lower flammable limit of 2.0% by volume; condenser and ventilation systems should hold the vapor zone below 25% LFL under normal running. Immersion sumps are typically maintained at 35–45 °C for rosin and no-clean flux removal. Water extracted from substrates and solder paste accumulates in the boil sump and must be monitored; once sump water content exceeds 0.2 wt%, drying rate decreases and the cleaning bath may develop visible phase separation in low-temperature zones.

    Ultrasonic immersion cleaning at 40 kHz with transducer power density of 10–15 W/L is used for bench-scale cleaning of ceramic substrates, stencils, and assembly tooling. The cavitation threshold of isopropyl alcohol is lower than water, but heat input from prolonged sonication can raise liquid temperature toward the flash point in open tanks. A maximum open-bath temperature of 35 °C is applied in equipment without cooling coils or inert blanketing.

    During spin-rinse drying, 99.5% IPA is injected through a 0.1 µm point-of-use filter to displace deionized water from substrate topography. The solvent surface tension of 21.7 mN/m at 20 °C improves dewetting from narrow gaps, but only if water remains at or below 0.2 wt%. When water exceeds this limit, residual water can remain in submicrometer trenches and produce drying marks after the isopropyl alcohol evaporates. Published data for this specific configuration is limited below 10 nm feature sizes; semiconductor manufacturers commonly move to 99.9% anhydrous IPA or alternative low-water solvents for critical final rinses.

    Application limits for 99.5% electronic-grade isopropyl alcohol
    ApplicationKey controlled parameterTypical limitFailure mode if exceeded
    PCB stencil and misprint cleaningIonic contamination1.56 µg NaCl equivalent/cm² per IPC-TM-650 2.3.25Electrochemical migration and leakage current
    Optical substrate cleaningNon-volatile residue≤5 ppmScatter sites and coating adhesion loss
    Semiconductor spin-rinse dryingWater≤0.2 wt%Watermark defects and residue in high-aspect-ratio structures
    Vapor degreasing sumpWater accumulation≤0.2 wt%Slow drying and phase separation in low-temperature zones

    For all four applications, the controlled impurity profile is meaningful only when the cleaning equipment itself is maintained; dirty sumps, spent wipers, and unfiltered gas dryers can transfer more contamination than the solvent.

    For substrates such as polycarbonate, acrylic, and some ABS blends, 99.5% isopropyl alcohol can induce environmental stress crazing when parts are highly stressed or immersed for extended periods. A practical limit of 5 min immersion at 25 °C is commonly set for polycarbonate housings, with immediate drying and no applied mechanical load. Silicone rubber, EPDM, and fluoropolymer seals show acceptable short-term resistance, while natural rubber and certain nitrile compounds swell or harden after repeated contact; seal compatibility should be verified by immersion testing per ASTM D471-16 before production use.

    The product is not recommended as a final rinse for chloride-sensitive metal interconnects if lot-specific chloride content exceeds 1 ppm. Verification by ASTM D512 is required, and the solvent should be kept isolated from strong oxidizers, concentrated nitric acid, and open ignition sources. The closed-cup flash point of 11.7 °C places the material in a flammable liquid category under OSHA 29 CFR 1910.106 and NFPA 30 storage rules; flammable-liquid cabinets and bonding and grounding of drums are mandatory in production surroundings.

    Static discharge during transfer from 200 L stainless steel drums requires grounding of both the drum and receiving vessel. Isopropyl alcohol resistivity is high, and flow through plastic lines can generate electrostatic charges. Initial filling rates should be limited below 1 m/s in non-conductive containers, or humidity should be maintained above 60% RH, or a grounded stainless steel dipper line should be used to dissipate charge. In cleanroom environments, transfer vessels should be pre-cleaned with the same solvent and dried with filtered nitrogen before use.

    When Cleanroom Packaging and Point-of-Use Filtration Become Binding Constraints

    When 99.5% electronic-grade isopropyl alcohol is used in semiconductor equipment maintenance, the packaging closure system contributes to final cleanliness. High-density polyethylene bottles are acceptable for many applications, but extractable hydrocarbons and ionic contaminants from closures can appear as a small NVR offset. Where container extractables must stay below 1 ppm for trace metal work, fluoropolymer-lined closures or glass containers with PTFE-lined caps are preferred. Packaging lines with filtered fill under ISO Class 5 conditions help keep particle counts at or below 25 particles/mL at 0.5 µm at the point of use.

    Quality control includes lot-specific assay, water by ASTM E203, NVR by ASTM D1353, acidity by ASTM D1613, chloride by ASTM D512, sulfate by ASTM D516, and trace metals by inductively coupled plasma mass spectrometry with detection limits at or below 0.1 ppb for critical elements. Particle counts are reported by calibrated optical particle counter. Differences from technical-grade material include absence of recycled solvent in the supply chain and controlled change management for raw material sources.

    For printed circuit assembly cleaning, the product leaves lower weak acid residue after evaporation than technical-grade IPA. The difference is detectable by ion chromatography with sensitivity below 0.1 µg/mL for chloride, nitrate, sulfate, and acetate. In facilities that require lot-to-lot reproducibility for automatic stencil cleaning machines, the 99.5% electronic grade is used in closed-loop solvent dispensing systems with 0.2 µm final filtration. The material is not supplied sterile and is not intended for direct medical injection or for cleaning surfaces that contact open wounds; users requiring endotoxin control must specify a dedicated USP or pharmaceutical excipient grade and verify by the relevant USP general chapter.